Showasaki
Universal Vibration Meter
Model - 1607
1. General-purpose type small vibrometer capable of measuring three modes of acceleration, velocity and displacement.
2. Wide-band and capable of measuring from a minute level to a large level.
3. Maneuverable in field measurement because of the small size and use of dry cells.
4. Capable of selecting a band matching a measurement object because of the built-in high-pass/low-pass filter.
5. Capable of wave analysis and level recording with the attached AC and DC output terminals.
6. Capable of appropriately using various sensors with ease by the easy setting of the sensor’s sensitivity.
Capable of using a remote charge converter and a detector with a built-in preamp in addition to an ordinary charge-output type detector.
Composition
Charge Vibrometer | MODEL-1607 | 1pc |
---|---|---|
Dry cell(6LR61) | 4pc | |
Instruction manual | 1copy | |
Option AC adaptor(AC100V) | 1pc |
Specifications
Charge Input Connector (BNC Connector on the front panel) | |
---|---|
Pickup Sensitivity (pC) | PU SENS×1:1.00-9.9pC/G PU SENS×10:10.0-99.9pC/G |
Max input charge | 10,000pC |
Voltage Input Connector (BNC Connector on the real panel) | |
Accuracy | Within 3% at 80Hz,100pC input |
Cal signal | 80Hz,±1V max. sinusoidal wave |
Supply current | 0.4-4mA (internal volume) |
Remote Charge Converter Input (Option) | |
Pickup Sensitivity (mV) | PU SENS×1:1.00-9.99mV/G PU SENS×10:10.0-99.9mV/G |
Max input voltage | ±10V |
Output | |
Indicator | Provided with dual scale 0-1,0-3 to indicate the
magnitude of amplitude selected with the meter selector or battery voltage. |
Overload lamp | When the linear range is exceeded in the internal circuit,LED lamp is on. |
AC OUT(BNC) | Vibration waveform output ±1V/FS Output resistance 100Ω 5mA Max.current |
DC OUT(BNC) | Trend recording as level output 0-1VDC Output resistance 100Ω 5mA Max.current |
Measuring Range | |
ACC1(G) | 1Hz-50kHz(1dB), 2Hz-20kHz(0.5dB) PU SENS×10:0.0316/0.1-100/316/FS PU SENS×1:0.316/1-1000/3160/FS |
ACC2(m/s2) | 1Hz-50kHz(1dB), 2Hz-20kHz(0.5dB) PU SENS×10:0.316/1-1000/3160/FS PU SENS×1:3.16/10-10000/31600/FS |
VEL(cm/s) | 3Hz-(0.5dB) PU SENS×10:0.316/1-1000/3160/FS PU SENS×1:3.16/10-10000/31600/F |
DISP(mm) | 3Hz-(0.5dB) PU SENS×10:0.1/0.316-316/1000/FS PU SENS×1:1/3.16-3160/10000/FS |
DISP2(mm) | 10Hz-(0.5dB) PU SENS×10:0.01/0.0316-31.6/100/FS PU SENS×1:0.1/0.316-316/1000/FS |
Filter | |
High-pass filter(Hz) | OUT(1Hz)/3/10/30/100 |
Low-pass filter(Hz) | 300/1k/3k/10k/OUT(50KHz) |
The Others | |
VEL(cm/s) | 3Hz-(0.5dB) PU SENS×10:0.316/1-1000/3160/FS PU SENS×1:3.16/10-10000/31600/F |
Vibrometer and Analyser (Model - 1022A) Digital Display Vibrometer (Model - 1332B) Peak Hold Type Digital Shockmeter (Model-1340A) Low Frequency Vibrometer And Analyser (Model-1422A) Vibro Switch (Model - 1500A) Vibration Monitor For Explosive Atmospheres (Model - 1500EX) Vibration Monitor (Model - 1590)
Universal Vibration Meter (Model - 1607) Multi Channel Vibration Meter (Model - 1607A) Showa Vibro Converter for Accelerometer (Model - 2501) 2 Wives Vibro Converter (Model - 2502) Digital Vibration Monitor (Model - 2590B) Charge Amplifier for Pressure Measuring (Model - 4001B) Charge Amplifier (Model - 4035)